Détail de l'auteur
Auteur A. Davranche |
Documents disponibles écrits par cet auteur (1)
Ajouter le résultat dans votre panier Affiner la recherche Interroger des sources externes
Radiometric normalization of SPOT-5 scenes: 6S Atmospheric Model versus Pseudo-invariant Features / A. Davranche in Photogrammetric Engineering & Remote Sensing, PERS, vol 75 n° 6 (June 2009)
[article]
Titre : Radiometric normalization of SPOT-5 scenes: 6S Atmospheric Model versus Pseudo-invariant Features Type de document : Article/Communication Auteurs : A. Davranche, Auteur ; G. Lefebvre, Auteur ; B. Poulin, Auteur Année de publication : 2009 Article en page(s) : pp 723 - 728 Note générale : Bibliographie Langues : Anglais (eng) Descripteur : [Vedettes matières IGN] Traitement d'image optique
[Termes IGN] analyse diachronique
[Termes IGN] Camargue
[Termes IGN] correction radiométrique
[Termes IGN] détection de changement
[Termes IGN] image SPOT 5
[Termes IGN] modèle atmosphérique
[Termes IGN] objet géographiqueRésumé : (Auteur) We compared the efficiency and robustness of two radiometric correction techniques applied to six SPOT-5 scenes used for assessing environmental changes of Camargue wetlands: the 6S atmospheric model and 86 pseudo-invariant features (PIFs) found in deep water, pine trees, roofs and sand. The few PIFs were selected subjectively following the low number of potentially invariant sectors available on the scenes. Both approaches provided a similar radiometric variation (6S = 4.3 percent; PIFs = 4.0 percent). The latter increased from water to pine trees, to roofs and sand, with five reference points per feature being identified as cost effective. The withdrawing of variant features among the PIFs across dates or points caused a significant decrease in radiometric variation, especially with 6S (6S = 2.8 percent, PIFs = 3.4 percent). As many as 31 point per type of PIFs would be necessary to provide a radiometric variation that is not significantly different from that obtained with 6S, whereas nearly 300 and 4,000 points per feature would be required to provide similar or better results than the 6S code, respectively. Use of a few PIFs remains a valid approach, as long as the invariant sectors cover a wide range of brightness and are represented by objects of which the radiometric variation has preliminarily been tested. Copyright ASPRS Numéro de notice : A2009-261 Affiliation des auteurs : non IGN Thématique : IMAGERIE Nature : Article DOI : 10.14358/PERS.75.6.723 En ligne : https://doi.org/10.14358/PERS.75.6.723 Format de la ressource électronique : URL article Permalink : https://documentation.ensg.eu/index.php?lvl=notice_display&id=29891
in Photogrammetric Engineering & Remote Sensing, PERS > vol 75 n° 6 (June 2009) . - pp 723 - 728[article]