Détail de l'auteur
Auteur Kurt Thome |
Documents disponibles écrits par cet auteur (1)
Ajouter le résultat dans votre panier Affiner la recherche Interroger des sources externes
In-situ transfer standard and coincident-view intercomparisons for sensor cross-calibration / Kurt Thome in IEEE Transactions on geoscience and remote sensing, vol 51 n° 3 Tome 1 (March 2013)
[article]
Titre : In-situ transfer standard and coincident-view intercomparisons for sensor cross-calibration Type de document : Article/Communication Auteurs : Kurt Thome, Auteur Année de publication : 2013 Article en page(s) : pp 1088 - 1097 Note générale : Bibliographie Langues : Anglais (eng) Descripteur : [Vedettes matières IGN] Acquisition d'image(s) et de donnée(s)
[Termes IGN] analyse comparative
[Termes IGN] capteur imageur
[Termes IGN] étalonnage en vol
[Termes IGN] étalonnage relatif
[Termes IGN] image EO1-ALI
[Termes IGN] image Landsat-ETM+
[Termes IGN] image Landsat-TM
[Termes IGN] image Terra-ASTER
[Termes IGN] image Terra-MODIS
[Termes IGN] incertitude des données
[Termes IGN] radiance
[Termes IGN] réflectanceRésumé : (Auteur) There exist numerous methods for accomplishing on-orbit calibration. Methods include the reflectance-based approach relying on measurements of surface and atmospheric properties at the time of a sensor overpass as well as invariant scene approaches relying on knowledge of the temporal characteristics of the site. The current work examines typical cross-calibration methods and discusses the expected uncertainties of the methods. Data from the Advanced Land Imager (ALI), Advanced Spaceborne Thermal Emission and Reflection and Radiometer (ASTER), Enhanced Thematic Mapper Plus (ETM+), Moderate Resolution Imaging Spectroradiometer (MODIS), and Thematic Mapper (TM) are used to demonstrate the limits of relative sensor-to-sensor calibration as applied to current sensors while Landsat-5 TM and Landsat-7 ETM+ are used to evaluate the limits of in situ site characterizations for SI-traceable cross calibration. The current work examines the difficulties in trending of results from cross-calibration approaches taking into account sampling issues, site-to-site variability, and accuracy of the method. Special attention is given to the differences caused in the cross-comparison of sensors in radiance space as opposed to reflectance space. The results show that cross calibrations with absolute uncertainties Numéro de notice : A2013-122 Affiliation des auteurs : non IGN Thématique : IMAGERIE Nature : Article nature-HAL : ArtAvecCL-RevueIntern DOI : 10.1109/TGRS.2013.2243841 En ligne : https://doi.org/10.1109/TGRS.2013.2243841 Format de la ressource électronique : URL article Permalink : https://documentation.ensg.eu/index.php?lvl=notice_display&id=32260
in IEEE Transactions on geoscience and remote sensing > vol 51 n° 3 Tome 1 (March 2013) . - pp 1088 - 1097[article]Exemplaires(1)
Code-barres Cote Support Localisation Section Disponibilité 065-2013031A RAB Revue Centre de documentation En réserve L003 Disponible