Sensors . vol 18 n° 9Paru le : 01/09/2018 |
[n° ou bulletin]
[n° ou bulletin]
|
Dépouillements
Ajouter le résultat dans votre panierGNSS-assisted integrated sensor orientation with sensor pre-calibration for accurate corridor mapping / Yilin Zhou in Sensors, vol 18 n° 9 (September 2018)
[article]
Titre : GNSS-assisted integrated sensor orientation with sensor pre-calibration for accurate corridor mapping Type de document : Article/Communication Auteurs : Yilin Zhou , Auteur ; Ewelina Rupnik , Auteur ; Paul-Henri Faure, Auteur ; Marc Pierrot-Deseilligny , Auteur Année de publication : 2018 Projets : 1-Pas de projet / Note générale : bibliographie Langues : Anglais (eng) Descripteur : [Vedettes matières IGN] Photogrammétrie numérique
[Termes IGN] chambre métrique
[Termes IGN] compensation par faisceaux
[Termes IGN] drone
[Termes IGN] modèle géométrique de prise de vue
[Termes IGN] orientation du capteur intégrée
[Termes IGN] point d'appui
[Termes IGN] récepteur GNSS
[Termes IGN] zone tamponRésumé : (auteur) With the development of unmanned aerial vehicles (UAVs) and global navigation satellite system (GNSS), the accurate camera positions at exposure can be known and the GNSS-assisted bundle block adjustment (BBA) approach is possible for integrated sensor orientation (ISO). This study employed ISO approach for camera pose determination with the objective of investigating the impact of a good sensor pre-calibration on a poor acquisition geometry. Within the presented works, several flights were conducted on a dike by a small UAV embedded with a metric camera and a GNSS receiver. The multi-lever-arm estimation within the BBA procedure makes it possible to merge image blocks of different configurations such as nadir and oblique images without physical constraints on camera and GNSS antenna positions. The merged image block achieves a better accuracy and the sensor self-calibrated well. The issued sensor calibration is then applied to a less preferable acquisition configuration and the accuracy is significantly improved. For a corridor acquisition scene of about 600 m , a centimetric accuracy is reached with one GCP. With the provided sensor pre-calibration, an accuracy of 3.9 cm is achieved without any GCP. Numéro de notice : A2018-388 Affiliation des auteurs : LASTIG MATIS+Ext (2012-2019) Thématique : IMAGERIE Nature : Article nature-HAL : ArtAvecCL-RevueIntern DOI : 10.3390/s18092783 Date de publication en ligne : 24/08/2018 En ligne : https://doi.org/10.3390/s18092783 Format de la ressource électronique : URL article Permalink : https://documentation.ensg.eu/index.php?lvl=notice_display&id=90803
in Sensors > vol 18 n° 9 (September 2018)[article]