Détail de l'auteur
Auteur P.E. Miller |
Documents disponibles écrits par cet auteur (1)
Ajouter le résultat dans votre panier Affiner la recherche Interroger des sources externes
In-flight photogrammetric camera calibration and validation via complementary lidar / A.S. Gneeniss in ISPRS Journal of photogrammetry and remote sensing, vol 100 (February 2015)
[article]
Titre : In-flight photogrammetric camera calibration and validation via complementary lidar Type de document : Article/Communication Auteurs : A.S. Gneeniss, Auteur ; Jon P. Mills, Auteur ; P.E. Miller, Auteur Année de publication : 2015 Article en page(s) : pp 3 - 13 Note générale : Bibliographie Langues : Anglais (eng) Descripteur : [Vedettes matières IGN] Acquisition d'image(s) et de donnée(s)
[Termes IGN] ajustement de paramètres
[Termes IGN] analyse comparative
[Termes IGN] auto-étalonnage
[Termes IGN] caméra numérique
[Termes IGN] compensation par faisceaux
[Termes IGN] données lidar
[Termes IGN] étalonnage en vol
[Termes IGN] extraction automatique
[Termes IGN] instrumentation Applanix
[Termes IGN] méthode des moindres carrés
[Termes IGN] point d'appui
[Termes IGN] UltraCamRésumé : (auteur) This research assumes lidar as a reference dataset against which in-flight camera system calibration and validation can be performed. The methodology utilises a robust least squares surface matching algorithm to align a dense network of photogrammetric points to the lidar reference surface, allowing for the automatic extraction of so-called lidar control points (LCPs). Adjustment of the photogrammetric data is then repeated using the extracted LCPs in a self-calibrating bundle adjustment with additional parameters. This methodology was tested using two different photogrammetric datasets, a Microsoft UltraCamX large format camera and an Applanix DSS322 medium format camera. Systematic sensitivity testing explored the influence of the number and weighting of LCPs. For both camera blocks it was found that when the number of control points increase, the accuracy improves regardless of point weighting. The calibration results were compared with those obtained using ground control points, with good agreement found between the two. Numéro de notice : A2015-050 Affiliation des auteurs : non IGN Thématique : IMAGERIE Nature : Article nature-HAL : ArtAvecCL-RevueIntern DOI : 10.1016/j.isprsjprs.2014.04.019 Date de publication en ligne : 16/05/2014 En ligne : https://doi.org/10.1016/j.isprsjprs.2014.04.019 Format de la ressource électronique : URL article Permalink : https://documentation.ensg.eu/index.php?lvl=notice_display&id=75236
in ISPRS Journal of photogrammetry and remote sensing > vol 100 (February 2015) . - pp 3 - 13[article]Exemplaires(1)
Code-barres Cote Support Localisation Section Disponibilité 081-2015021 RAB Revue Centre de documentation En réserve L003 Disponible