Détail de l'auteur
Auteur Miriam Zámečníková |
Documents disponibles écrits par cet auteur (1)



Methods for quantification of systematic distance deviations under incidence angle with scanning total stations / Miriam Zámečníková in ISPRS Journal of photogrammetry and remote sensing, vol 144 (October 2018)
![]()
[article]
Titre : Methods for quantification of systematic distance deviations under incidence angle with scanning total stations Type de document : Article/Communication Auteurs : Miriam Zámečníková, Auteur ; Hans Neuner, Auteur Année de publication : 2018 Article en page(s) : pp 268 - 284 Note générale : Bibliographie Langues : Anglais (eng) Descripteur : [Vedettes matières IGN] Topographie
[Termes IGN] angle d'incidence
[Termes IGN] erreur systématique
[Termes IGN] Multistation
[Termes IGN] tachéomètre électronique
[Termes IGN] télémètre laser terrestreRésumé : (Auteur) If scanning total stations (TLS+TS) are used in scanning mode for high accurate engineering applications, the systematic influence of the incidence angle (IA) on the reflectorless distance measurement has to be eliminated. At present, methods for quantifying the systematic distance deviations under IA are missing because the measured points are not reproducible. In this paper, three such methods are presented. They are conditional on the used instruments and the required accuracy. These methods are validated with respect to specified framework conditions. The distance deviations are derived in all three methods as difference between the distance measured with TLS+TS in the scanning mode (DTLS) and the corresponding reference distance (Dref). The Dref is determined in three steps: measurement of a high accuracy network, measurement for determining the starting point of the Dref; object measurement to determine the endpoints of Dref. The corresponding DTLS and Dref are identified by means of the horizontal direction Hz (HzTLS and Hzref) and the vertical angle V (VTLS and Vref), both pairs of angles referring to the same origin marked by the axis of the common coordinate system. Depending on the used method, the Dref is determined with a standard uncertainty of 0.1–0.3 mm (at a distance of 30 m). The quantified influence of IA on the distance measurement of the Leica MS50 at a distance of 30 m to a granite plate varies in the interval of 0.8 mm. The strong variation due to the IA occurs from 0 to 20 gon, its effect is stable from 20 to 60 gon. Numéro de notice : A2018-391 Affiliation des auteurs : non IGN Thématique : IMAGERIE/POSITIONNEMENT Nature : Article nature-HAL : ArtAvecCL-RevueIntern DOI : 10.1016/j.isprsjprs.2018.07.008 Date de publication en ligne : 03/08/2018 En ligne : https://doi.org/10.1016/j.isprsjprs.2018.07.008 Format de la ressource électronique : URL article Permalink : https://documentation.ensg.eu/index.php?lvl=notice_display&id=90825
in ISPRS Journal of photogrammetry and remote sensing > vol 144 (October 2018) . - pp 268 - 284[article]Réservation
Réserver ce documentExemplaires (3)
Code-barres Cote Support Localisation Section Disponibilité 081-2018101 RAB Revue Centre de documentation En réserve L003 Disponible 081-2018103 DEP-EXM Revue LASTIG Dépôt en unité Exclu du prêt 081-2018102 DEP-EAF Revue Nancy Dépôt en unité Exclu du prêt